FencingWise

Powder-Coating Adhesion: Read a Factory Test Report

A factory adhesion report needs a named method, identified specimen and agreed acceptance criterion. We distinguish a cross-cut classification from a pull-off strength and connect the result to the coating batch supplied. A bare number or a photograph of a cut lattice cannot establish shipment conformity.

By FencingWise Editorial Team · Updated 3 November 2026.

Distinguish a rating from a pull-off strength

A cross-cut or cross-hatch assessment examines coating separation around a cut pattern. Its classification is not a force value in megapascals. A pull-off test uses a different procedure and produces a different type of result.

Use the governing adhesion-test method and agreed edition for the actual coating. Confirm the method's coating-thickness scope before choosing the test arrangement.

Do not select a method simply because the factory owns the tool. Component shape, coating thickness, substrate and the required evidence determine whether it is suitable.

Cross-hatch cut pattern on a dark coated metal sample
A cross-hatch cut pattern illustrates a classification test. Its appearance alone is not a reported rating or a pull-off strength.

Check whether the test surface represents the order

If a flat witness panel is used for coating tests, link it to the relevant substrate preparation, powder material and cure cycle. Record what the sample represents and what remains outside its evidence. A generic coated coupon from another run cannot establish adhesion on the shipment, and a test method suited to a flat panel may not suit a wire intersection.

A fence wire or tight recess may not provide the flat area required for a valid lattice. Avoid forcing a standard cutter around a small curved wire and reporting the outcome as a normal flat-panel test.

If a witness coupon is used, record what it represents and what it does not. It can support process control, while component inspection still needs to address cut edges, welds and difficult geometry.

Black coated steel fence installed outside a commercial building
An installed coated fence has wires, rails and joints that a flat test coupon cannot fully represent.

Prepare the test record before making a cut

Record:

  • Sample and production-lot identification.
  • Substrate and metallic coating, if present.
  • Organic coating products and number of layers.
  • Measured dry-film thickness at the relevant area.
  • Test method, edition and selected cutting arrangement.
  • Conditioning and environmental information required by that method.
  • Tape or other loose-particle-removal method, where applicable.
  • The agreed acceptance criterion.

The test damages the coating. Agree the test location and the repair or disposal arrangement in advance. An unrecorded scratch on a finished gate is neither a controlled test nor a satisfactory repair record.

Follow one complete procedure

The practical sequence is to identify and condition the sample, measure the film, select the appropriate cutter, make the prescribed pattern, remove loose material using the method's procedure, inspect and classify.

Select cutter spacing and the number of cuts using the agreed standard and measured coating thickness. ISO 2409 and ASTM D3359 have their own selection and execution rules; the procedures should not be mixed.

Use the complete current procedure for details such as cutting, tape application and removal. Small differences in execution can affect the result. Record invalid attempts separately and repeat them according to the applicable method rather than keeping only the most favourable photograph.

Hands applying tape to a cross-hatch cut on a dark coated metal sample
Tape is applied to a cut lattice during an adhesion check. This example photograph is not a test record for a FencingWise order.

Read the rating in the correct direction

Record the standard alongside the classification. An intact lattice is ISO 2409 class 0 or ASTM D3359 Method B class 5B; the scales run in opposite numerical directions. The instrument manufacturer’s comparison illustrates the labels, but the specified standard governs the actual procedure and acceptance. Elcometer cross-hatch classification guidance. ISO 2409 scope.

Report entry What can be concluded
“5” with no method Result is ambiguous
“ISO 2409, class 0” Identifies the ISO classification and method
“ASTM D3359 Method B, 5B” Identifies the ASTM classification and method
“Adhesion 8 MPa” Describes a different type of result; method and failure mode still needed

Do not convert a class number into a percentage of bond strength. The classification describes the observed test outcome, not how much of the original structural strength remains.

Make a decision against the agreed criterion

Assume a fictional order requires ISO 2409 class 0 at each of three identified test locations. The reported results are 0, 0 and 1.

Read each required location against the agreed criterion before looking at a summary. An average of classification numbers cannot release a location that fails an individual acceptance requirement.

Two locations meet that assumed criterion; one does not. An arithmetic average of 0.33 should not be used to declare the sample compliant with an “each location class 0” requirement.

Record where separation occurred: at the metal interface, between organic layers or within a layer where identifiable. This helps direct investigation. A classification alone may show a problem without identifying whether preparation, contamination, cure or intercoat compatibility caused it.

Keep process correction linked to the failed lot

When a valid result does not meet the order, identify the affected production scope and agree the investigation and retest plan. Recoating a sample differently and obtaining a better result does not release the original lot.

Retain photographs, individual results and the final disposition. After authorised repair or reprocessing, repeat the required checks on representative material with traceability intact.

Use adhesion alongside the specified thickness, appearance and corrosion-related checks. The salt-spray article explains another part of the evidence; neither test alone establishes the full outdoor service life of a fence.

Specify the evidence before testing

Provide the coating system, governing method and required sample basis. Agree destructive-test locations and the disposition of tested parts, then request individual results and failure records. Link the report to the coated double wire panel specification.